Energy performance certificate (EPC) recommendation report


Share this report

  • Email


1 Ebenezer Place BANGOR LL57 1HL
8846-1557-7696-4877-8144
11 October 2031

Energy rating and EPC

This property’s energy rating is E.

For more information on the property’s energy performance, see the EPC for this property.

Recommendations

Changes that may pay for themselves within 3 years
Recommendation Potential impact on carbon emissions
Consider replacing T8 lamps with retrofit T5 conversion kit. Medium
Introduce HF (high frequency) ballasts for fluorescent tubes: Reduced number of fittings required. Low
In some spaces, the solar gain limit defined in the NCM is exceeded, which might cause overheating. Consider solar control measures such as the application of reflective coating or shading devices to windows. Medium
Add time control to heating system. Medium
Add optimum start/stop to the heating system. Medium
Changes that may pay for themselves within 3 to 7 years
Recommendation Potential impact on carbon emissions
The default heat generator efficiency is chosen. It is recommended that the heat generator system be investigated to gain an understanding of its efficiency and possible improvements. Low
Add local temperature control to the heating system. Medium
Add weather compensation controls to heating system. Medium
Some loft spaces are poorly insulated - install/improve insulation. Medium
Add local time control to heating system. Medium
Changes that may pay for themselves in over 7 years
Recommendation Potential impact on carbon emissions
Some solid walls are poorly insulated - introduce or improve internal wall insulation. Medium
Carry out a pressure test, identify and treat identified air leakage. Enter result in EPC calculation. Medium
Consider installing an air source heat pump. High
Install more efficient water heater. Medium
Consider installing building mounted wind turbine(s). Low
Additional recommendations
Recommendation Potential impact on carbon emissions
The default chiller efficiency is chosen. It is recommended that the chiller system be investigated to gain an understanding of its efficiency and possible improvements. High

Property and report details

Report issued on
12 October 2021
Total useful floor area
57 square metres
Building environment
Heating and Natural Ventilation
Calculation tool
CLG, iSBEM, v5.6.b, SBEM, v5.6.b.0

Assessor’s details

Assessor’s name
William Morris
Telephone
01690 750 288
Employer’s name
William Morris Energy Assessments
Employer’s address
Gwynant, Dolwyddelan, Conwy
Assessor ID
STRO002869
Assessor’s declaration
The assessor is not related to the owner of the property.
Accreditation scheme
Stroma Certification Ltd

Other reports for this property

If you are aware of previous reports for this property and they are not listed here, please contact us at dluhc.digital-services@levellingup.gov.uk or call our helpdesk on 020 3829 0748 (Monday to Friday, 9am to 5pm).

There are no related reports for this property.